A thick glass door is usually a decorative door with the thickness of 12 mm or higher. It is generally constructed from two parts: the movable fan along with the fixed glass. The door frame is divided into metal, copper and aluminum metal. 1 Before the building is completed, check whether the elevation with the ground and the height on the structure at the top with the door frame meet the structure requirements. Determine the position on the door frame and how to install the glass. Choose the insulated glass reported by the design requirements. Concluded profile door frame, limit groove, plate and tumbler glue, floor spring, real wood screw, self-tapping screw and various auxiliary materials.
2 Installation points involving fixed door frame thick glass (1) Release and positioning Reported by the design requirements, the position in the door frame is released, and the fixed and also movable part installation manipulate lines are determined.
(2) The width of the stainless steel limit groove limit groove for the top of the installation door frame ought to be greater than the cup thickness of 2~4mm, as well as groove depth is 10~20mm.
(3) Install the stainless veneer on the surface first, then glue the steel panel to the wood made side. The aluminum alloy square tube might be fixed on the frame column with an metal corner code, or can be fixed on the embedded embedded portion by screws.
(4) Lower glass (usually pre-cut, then tempered and transported for the site for installation). The dimensions on the bottom, middle and top on the actual volume should end up being measured, and the cut size in the minimum size of the glass width ought to be selected. If the dimensions measured inside upper, middle and lower is also the same, the size can be cut, the width is under the measured size of 2-3 mm, and the height is less than Less than six mm. For the structure glass, the chamfered edging is intended to be carried out on that four sides by hand-held oil-coated stone, with a chamfer bigger of 2 mm.
(5) Install the glass having a glass suction cup to lift the thick goblet up, insert the thick glass plate into the limit groove at the top of the door body, and then place it to the bottom bracket so how the edge of the solid glass plate just seals along side it. The stainless steel trim of the frame column faces this seam.
(6) The glass is fixed around the bottom bracket and the pressure clamp strip is installed, about 4mm away from the thick glass dish. Then apply the universal glue about the strip and stick the metal plate on the strip.
(7) Inject the glass seal into the top limit groove and the bottom support, and inject the glass glue on the joint between the thick glass and also the frame column, so the glass glue forms a new uniform straight line in the gap. Finally, scrape journey excess glass glue and also wipe the glue having a clean cloth. When heavy glass is butted, the joint ought to be kept at a long distance of 2~3mm. The thick glass edge is required to be chamfered. After the two thick glass sit and fixed, the glass glue can be used to inject into your gap. After filling, your thick glass is packed. Squeeze the glass glue upon both sides and wipe the glue that has a clean cloth.
3 The installation point from the movable door leaf solid glass The thick goblet movable door leaf features no door frame. The opening and closing in the movable door leaf is realized because of the hardware hinged to top of the and lower rails on the frame.
(1) Floor spring mounting ground spring is an automatic door closing system installed under various entrance fans.
(2) Mark top of the and lower rails with the door leaf, and fix the pin hole plate of the rotation pin and the rotation shaft connection plate belonging to the floor spring by the particular wire. Refer to the installation instructions attached to the ground spring product for installation.
(3) Drill the holes in the door handle (usually necessary to be processed when purchasing thick glass). Note the height dimension of the thick glass should add some mounting portion that is inserted in to the upper and lower side rails. Usually the cut dimension of thick glass ought to be less than about 5mm associated with measurement size for change.
(4) Install the top and lower rails within the upper and lower sides from the thick glass door plus measure the height on the door. If the upper and lower edges of the door leaf are not even close the specified value from the gap between the door frame and the ground, the wooden splint is usually placed under the glass from the upper and lower side rails. If the door leaf top exceeds the installation size, the excess portion with the thick glass door leaf has to be cut.
(5) After environment the height, fix the upper and lower rails. For the gap between the thick glass and the metal upper and lower rails, a small wooden strip is inserted simultaneously, and then the cup glue is injected in to the gap between the compact wooden strip, the thick glass plus the crosspiece.
(6) Door enthusiast positioning installation. First, adjust the positioning pin around the door frame beam using its own adjustment screw to the beam plane 1~2mm. Next erect the glass entrance leaf, align the hole position on the rotating pin connector with the lower crosspiece of the door leaf considering the rotation pin of the actual spring, and turn the door leaf to fit the hole into the particular pin. Then, with the pin axis since the axis, turn the entry leaf 90° (to suitable the door leaf whenever turning), so that the door leaf and the door beam are from right angles. At this occassion, the hole of this rotating connecting piece while in the crosspiece of the door leaf may be aligned on the gate frame beam. The positioning pin is proved and the positioning pin is proved, and inserted into the hole on the door leaf cross-rotating pin connecting member is approximately 15 mm. Install the particular glass door handle. Before installation, apply a little glass glue to the part where the handle is inserted to the glass. When the deal with is assembled, the root is closely mounted on the glass, and then the correcting screw is tightened to make sure that the handle is not necessarily loose.